General Data
Operating Temp. Range | -200C to + 500C | Dimensions (H*W*D) | 220x145x70 mm |
Relative Humidity | 0-100% | Protection Degree | IP65 |
Operating Altitude | < 4000m | Safety Regulation | IEC 62109 |
Cooling | Natural Convection | Pollution Degree | PD2 |
Weight | 2.3 kg | Overvoltage Category | OVC II |
Environment | Outdoor | Location Classification | Suitable for Wet areas |
Heating Start Power | 250 W | Factory Set Shut temp | 600C or 700C |
User Interface | LCD & LED Indication | Country of Manufacture | Australia |
PV String Input Data
Max. DC Input Power | 3.84 kW | Array Strings | 2 |
Max. DC Input Voltage | 270 VDC | String Configuration | Parallel |
Max. Input Current | 22.0 A | Max DC Voltage Output | 270VDC |
Max. Output | 3.84 kW | Max. Output Current | 22.0 A |
Input Reverse Polarity Protection | NO | Input Over Voltage Protection | YES |
Max power must not be exceeded. 3.84kW can be either 270V @14.2A or 174V @ 22.0A or in between.P=IR (Volts x Current), 3840W must not be exceeded.
Supplied Cabling Data
Main Array Cable | MC4 Connection | NTC Cable | 2 x 0.75mm2 |
Element Cable | 3 x 4mm2 | Cable Insulation | Flex Rubber UV Stable |
Insulation Type | Flex PVC UV Stable | Insulation Rating | 0.6/1kV |
Conduit | 25mm OD x 19mm ID UV Stable PV Approved |
Models
Model | Output 1 | Output 2 |
PV360 | Heating Element via PVOTC | None |
PV360BMS | Heating Element via PVOTC | Output to Battery Management System |
PV360SWT | Heating Element via PVOTC | Output to Inverter |
Nominal Single Panel Data
Nom.Panel Voltage VOC | 44 V Max. | Nom. Max. Power Voltage (V) | 32.5 V |
Short Circuit Current Isc | 11.0 A Max. | Max. Power Current (A) | 11.0 A |